A hardware analyzer measures a value such as O2, CO or NOx. Virtual analyzers, also known as soft sensors, work differently. They work out the same value from other plant data. A tested model does the math. The same idea powers Predictive Emissions Monitoring Systems (PEMS).
The Problem with Relying on One Analyzer
If you maintain hardware analyzers, these questions will sound familiar:
- Is the analyzer giving accurate readings right now?
- Is it accurate only because someone calibrated it yesterday?
- Is the vendor’s test interval right for your site?
Without a second check, the answer is often a guess.
How Virtual Analyzers Help
Take an O2 analyzer on a furnace stack. It plays a key safety role in burner control. A virtual analyzer can use air flow, fan power, damper position and fuel flow. From these, it predicts the O2 you should see.
If the two readings differ, the analyzer may be drifting. That tells you it needs a check. Virtual analyzers rely on several inputs, not just one. As a result, they give you a clear, fact-based view of analyzer health.
Typical Benefits
- Lower cost to install and maintain than many hardware units
- No sample lines, test gases or analyzer huts
- A backup reading while the hardware unit is down for repair
- Early warning of drift or failure
- A good fit where hardware is hard or costly to install
Limitations to Keep in Mind
- The model is only as good as its data. It works best within the range it learned from.
- After big process changes, you need to review and update the model.
- You still need regular checks against reference tests.
- For emissions reporting, the system must meet the rules, such as EPA PS-16 for PEMS.
Learn more about PEMS and software-based emissions monitoring.